Brand: Emerson
Model number:VE4006P2
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:3.17kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
EMERSON VE4006P2 Central control module
INQUIRE NOW
Products Name: EMERSON VE4006P2 Central control module
PRODUCT DESCRIPTION
Product Detailed Description:
Emerson pilot-operated pressure-reducing regulators are advanced control devices designed to accurately reduce a higher inlet pressure to a precisely controlled, lower outlet pressure. Unlike direct-operated regulators that rely on a spring acting directly on the main valve, pilot-operated regulators use a small, highly sensitive pilot regulator to control the main valve. This two-stage control system (pilot and main valve) allows for superior accuracy, faster response times, and higher flow capacities.
How it works:
Pilot: The pilot regulator senses the downstream pressure. If the downstream pressure deviates from the setpoint, the pilot adjusts a small flow of fluid (typically the process fluid itself) to load or unload the main valve's diaphragm or piston.
Main Valve: The main valve is the primary flow control element. Its position (and thus the flow through it) is controlled by the pressure differential created across its diaphragm or piston by the pilot. This allows the main valve to open or close to precisely maintain the desired downstream pressure.
Key Design Features:
Balanced Plug Design: Many models feature a fully balanced plug design which reduces the forces required to actuate the main valve, leading to lower differential pressure requirements for full stroke and better control.
Radial Seal Design: Often incorporates radial seals for lower sealing forces and reduced wear around seating surfaces.
Modular Design: Facilitates ease of maintenance and component replacement.
Tight Shutoff: Designed to provide bubble-tight shutoff, minimizing leakage when downstream demand is met.
Noise Attenuation Options: Some models offer integrated or optional noise attenuation features (e.g., silencers) to reduce noise levels in high-pressure drop applications.
Versatile Construction Materials: Available with various body and trim materials to ensure compatibility with a wide range of fluids and temperatures.
Product Parameters:
Emerson offers a vast portfolio of pilot-operated pressure-reducing regulators for different applications and fluid types (air, fuel gas, liquids, process gases, steam, etc.). Specific parameters vary significantly by model (e.g., Fisher Type FL, Type 99, PRX Series pilots). However, common parameters include:
Inlet Pressure Range: Can vary from low pressure (e.g., less than 0.25 psi) to very high pressures (e.g., up to 5000 psi / 345 bar).
Outlet Pressure Range: Wide range of achievable outlet pressures, from very low (e.g., 2 in. w.c. / 5 mbar) to high pressure (e.g., up to 1160 psig / 80 bar).
Body Sizes: Available in a wide range of NPS (Nominal Pipe Size) / DN (Diameter Nominal), e.g., NPS 1 to 20 / DN 25 to 500.
End Connection Styles: Common styles include NPT (threaded), Class 125/150/250/300/600 RF (Raised Face Flanged), and PN ratings.
Accuracy Class: Often rated with high accuracy, typically up to ±1% of the setpoint.
Lock-Up Pressure Class: Specifies the pressure increase above the setpoint at zero flow, typically up to +5%.
Minimum Operating Differential Pressure: The minimum pressure difference between inlet and outlet required for stable operation (e.g., 0.2 bar / 7.25 psig).
Temperature Capabilities: Dependent on construction materials (elastomers, metals), standard ranges might be -20°C to 82°C (-4°F to 180°F), with extended ranges for specialized applications.
Flow Capacity (Cv / Cg): High capacity, often exceeding that of direct-operated regulators of comparable size.
Response Time: Typically fast, e.g., ≤1 s.
Certifications: Often meet various international standards (e.g., EN, ISO, ASME).
Product Advantages:
High Accuracy and Stability: The pilot control provides much finer and more stable control of the downstream pressure compared to direct-operated regulators, even with varying inlet pressures or flow demands.
High Flow Capacity: Can handle significantly larger flow rates for a given body size, making them suitable for high-capacity applications.
Reduced Droop (Offset): Exhibits less "droop" (deviation from the setpoint) as flow demand increases, maintaining a more consistent outlet pressure.
Fast Response: Quickly respond to changes in upstream pressure or downstream demand.
Versatility: Available for a wide range of fluids, pressures, temperatures, and applications.
Tight Shutoff: Minimizes leakage at zero flow, reducing product loss and enhancing efficiency.
Quiet Operation: Some designs and optional features (like silencers) help reduce noise levels in high-pressure drop applications.
Ease of Maintenance: Modular designs and fewer moving parts in the main valve can simplify maintenance.
Precautions:
Proper Sizing and Selection: Critical to select the correct regulator model and size based on maximum and minimum inlet pressure, required outlet pressure range, maximum and minimum flow rates, fluid type, and temperature. Improper sizing can lead to instability or insufficient performance.
Installation:
Upstream Filtration: Always ensure the gas or fluid entering the regulator is clean and free of debris. Use upstream filters to prevent damage to the pilot and main valve.
Vertical Mounting: Regulators should typically be installed vertically in an upright position to ensure proper operation.
Discharge Piping: The regulator outlet and any separate drains should be piped or vented to a safe location. Discharge piping should be properly supported to withstand reactive thrust forces.
Isolation Valves: Use isolation block valves for safe maintenance, ensuring any trapped fluid between the block valve and the regulator is safely vented.
Cleanliness: Maintain cleanliness during storage and installation to prevent foreign materials from entering the valve.
Safety:
Depressurize System: NEVER attempt to remove or adjust the regulator while the system is pressurized. Isolate the valve from process pressure and relieve pressure on both sides before maintenance.
Personal Protective Equipment (PPE): Always wear proper safety gear (gloves, eyewear, hearing protection) when working near pressurized valves.
Intended Use: Do not use the regulator for purposes other than its intended use (e.g., as a control valve for continuous operation or as a block valve).
Maintenance:
Regular Inspection and Testing: Regulators must be periodically inspected, tested, and reconditioned to ensure correct function and seat tightness.
Genuine Parts: Use only genuine Emerson replacement parts for repairs.
Troubleshooting: Consult the specific product's instruction manual for troubleshooting guidelines if performance issues arise.
Product Applications:
Emerson pilot-operated pressure-reducing regulators are widely used in a diverse range of industries and applications where precise and high-capacity pressure control is required:
Oil & Gas Industry:
Natural gas transmission and distribution systems (city gate stations, farm taps, pipeline pressure reduction).
Fuel gas supply to boilers, furnaces, and industrial ovens.
Tank blanketing and vapor recovery systems to prevent contamination and product loss.
Power Generation:
Fuel gas supply to power plants and turbines.
Steam pressure reduction for process loads.
Chemical and Petrochemical Processing:
Process gas pressure regulation for various chemical reactions and industrial processes.
Liquid pressure control.
Manufacturing and Industrial Facilities:
Compressed air systems for tools and machinery.
Industrial ovens, dryers, and heat exchangers.
HVAC Systems:
Steam and fluid pressure control in heating and cooling systems.
Water Treatment:
Water pressure management in municipal and industrial water systems.
Food & Beverage / Pharmaceutical / Biotechnology:
Sanitary pressure control for hygienic applications.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
EMERSON | 13A0068G02 | EMERSON | 13A0068G02 |
EMERSON | 13A0069G01 | EMERSON | 13A0069G01 |
EMERSON | 13A0070H17 | EMERSON | 13A0070H17 |
EMERSON | 13A0072G01 | EMERSON | 13A0072G01 |
EMERSON | 13A0073G08 | EMERSON | 13A0073G08 |
EMERSON | 13A0076G01 | EMERSON | 13A0076G01 |
EMERSON | 13D0092G01 | EMERSON | 13D0092G01 |
Emerson | 14-193-100-562 | Emerson | 14-193-100-562 |
Emerson | 142U3C300VACAA165240 | Emerson | 142U3C300VACAA165240 |
Emerson | 143D1370G0001 | Emerson | 143D1370G0001 |
Emerson | 149D934G01 | Emerson | 149D934G01 |
EMERSON | 14A0003G01 | EMERSON | 14A0003G01 |
EMERSON | 14A0009G03 | EMERSON | 14A0009G03 |
EMERSON | 14A0009G05 | EMERSON | 14A0009G05 |
EMERSON | 14A0009G08 | EMERSON | 14A0009G08 |
EMERSON | 14A0041G02 | EMERSON | 14A0041G02 |
EMERSON | 14A0042G01 | EMERSON | 14A0042G01 |
EMERSON | 14A0043G02 | EMERSON | 14A0043G02 |
Emerson | 150-B180 | Emerson | 150-B180 |
EMERSON | 15A0016G01 | EMERSON | 15A0016G01 |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020